古高 和禎; 大図 章; 藤 暢輔
Nuclear Engineering and Technology, 55(11), p.4002 - 4018, 2023/11
被引用回数:0 パーセンタイル:0.01(Nuclear Science & Technology)An integrated neutron interrogation system has been developed for non-destructive assay of highly radioactive special nuclear materials, to accumulate knowledge of the method through developing and using it. The system combines a differential die-away (DDA) measurement system for the quantification of nuclear materials and a prompt gamma-ray analysis (PGA) system for the detection of neutron poisons which disturb the DDA measurements; a common D-T neutron generator is used. A special care has been taken for the selection of materials to reduce the background gamma rays produced by the interrogation neutrons. A series of measurements were performed to test the basic performance of the system. The results show that the DDA system can quantify plutonium of as small as 20~mg and it is not affected by intense neutron background up to 4.2~TBq and gamma ray of 2.2~TBq. As a result of the designing of the combined system as a whole, the gamma-ray background counting rate at the PGA detector was reduced down to s even with the use of the D-T neutron generator. The test measurements show that the PGA system is capable of detecting less than 1~g of boron compound and about 100~g of gadolinium compound in~30 min. This research was implemented under the subsidy for nuclear security promotion of MEXT.